Florida’s Wastewater Infrastructure Experts

Sectional Pipe Lining

Request Help Right Away
Sectional Pipe Lining & When It's the Right Method

Sectional Cured-In-Place Pipe (CIPP) Lining Services in Florida

Flotech Environmental provides sectional cured-in-place pipe (SCIPP) lining services for municipalities, utility authorities, general contractors, property managers, and engineering firms throughout Florida. Sectional CIPP is a trenchless rehabilitation method. It installs a resin-saturated fiberglass liner across localized defects. These include circumferential and longitudinal cracks, offset and open joints, root-intruded joints, and infiltration points. The liner is bonded to the host pipe under steam pressure, restoring structural integrity without excavation. When defects are isolated rather than continuous, this avoids the cost and surface disruption of full-length lining or open-cut replacement.

Sectional CIPP is the appropriate rehabilitation method when CCTV inspection identifies isolated defects within an otherwise structurally sound pipe segment. It is most effective where damage is concentrated at joints, lateral connections, or short cracked sections rather than distributed along the pipe. This method also fits when the host pipe still has enough structural capacity for a partially deteriorated liner design under ASTM F1216 or ASTM F2599. It is a good choice when open-cut replacement is impractical due to depth, traffic, restoration costs, or utility conflicts. It is also preferred when full-length CIPP would exceed the necessary scope based on defect length and concentration.

Frequently Asked Questions

Sectional Pipe Lining FAQs

Here are some of the most common questions about our services, response times, and how we support infrastructure projects across Florida.

Full CIPP (cured-in-place pipe) lining rehabilitates an entire pipe segment from manhole to manhole. Sectional lining (SCIPP) targets a specific short section of pipe where there is an isolated defect. Sectional lining is typically more cost-effective when only one or a few spots require repair.

Sectional pipe lining can repair cracks, joint failures, offset joints, root intrusion, and other localized structural defects in sanitary sewer and stormwater pipelines. It is also used to stop active infiltration at specific locations.

Sectional lining is available for a range of pipe sizes and materials, including clay, concrete, PVC, and ductile iron. Flotech's technicians assess existing conditions and determine the appropriate lining system for each application.

Yes. Flotech performs CCTV inspection before pipe lining to confirm pipe conditions and defect locations, and a post-lining inspection to verify that the repair meets specifications and the liner is properly cured and installed.

Our Sectional Pipe Lining Services

Sectional Cured-In-Place Pipe Lining (SCIPP)

Sectional CIPP installs a short fiberglass liner saturated with thermoset resin across a localized defect within an otherwise sound pipe segment. The liner is positioned with an inflatable packer, pressed against the host pipe wall under air or steam pressure, and cured in place. Once cured, the liner bonds to the host pipe, restoring structural continuity, eliminating infiltration, and arresting further deterioration. Flotech installs SCIPP in gravity sanitary sewers and stormwater pipes from 6″ to 96″ in diameter. We work from existing manholes across Tampa, Miami, Fort Lauderdale, and Orlando, with no excavation or surface disruption. A typical crew installs multiple sections per shift, with production rates driven by pipe diameter, defect spacing, and access conditions.

Pre-Lining Cleaning and CCTV Inspection

Successful CIPP installation depends on a clean, prepared host pipe. Before lining, Flotech cleans the pipe with high-pressure water jetting at up to 80 GPM and 2,500 PSI. This removes grease, scale, sediment, roots, and protruding service connections that would weaken liner adhesion or fit. A pre-lining CCTV inspection verifies pipe condition, locates defects to the linear foot, and identifies lateral positions for post-cure reinstatement. Post-installation CCTV documents liner placement, surface finish, and lateral reinstatement quality for project close-out and warranty acceptance.

Lateral Reinstatement

After sectional CIPP installation, any service laterals temporarily covered by the liner must be reopened to restore flow from connected properties. Flotech’s robotic cutters reinstate lateral openings under live CCTV control, cutting precise, deburred openings that maintain hydraulic capacity and prevent debris snagging or root re-entry. All reinstatements are documented with post-cut CCTV for as-built records.

Point Repair and Chemical Grouting

Some joints, hairline cracks, and lateral connections leak but do not need structural repair. For these, Flotech injects chemical grout (acrylamide or acrylate gel) through packers under controlled pressure. Grouting seals the defect against groundwater infiltration without altering pipe diameter and is typically applied where the host pipe retains full structural integrity but exhibits leakage at joints. Flotech evaluates each defect against MACP and PACP condition data and recommends the most cost-effective rehabilitation method, including sectional CIPP, chemical grouting, or open-cut replacement, based on structural condition, infiltration severity, and project economics.

The Flotech Advantage

Built for Modern Pipeline Rehabilitation

Flotech combines proven field experience, certified rehabilitation crews, and statewide resources to deliver reliable trenchless pipe repair solutions across Florida.

Proven Experience:

Over 12 million linear feet of pipeline cleaned and inspected and extensive trenchless rehabilitation experience across Florida, supporting municipal utilities, FDOT projects, and private development

Certified Crews:

NASSCO PACP and MACP-certified technicians trained in sectional CIPP, full-length CIPP, chemical grouting, and supporting trenchless rehabilitation methods, operating under documented safety and confined-space entry protocols

Minimally Invasive:

Sectional CIPP eliminates excavation, traffic control, pavement restoration, and utility conflict risk, with all work performed through existing manhole access

Statewide Coverage:

Four offices in Miami Springs, Hollywood, Orlando and Brandon enable rapid deployment and continuous service across Florida

Testimonials

Feedback from the Field

Our work is measured not just by what we complete, but by the trust we build along the way. Here’s what clients across Florida have to say about working with Flotech.

Areas We Serve

Where Florida Needs Pipe Repair, We’re There

Flotech Environmental provides sectional pipe lining and pipe relining services throughout Florida, with four offices in Miami Springs, Hollywood, Orlando and Brandon. We serve municipalities, contractors, property managers, HOAs, and engineering firms across the state.

Contact Flotech

Let’s Talk About Your Infrastructure Needs

Share a few details about your infrastructure needs, and a Flotech specialist will follow up to discuss the right next step.

Phone
(866) 299-3323
Email
[email protected]
White Flotech logo on a transparent background